Small size reference system

The small size reference system is constructed with 5000 Tags of data type double. Tags are getting live data from OPC UA data source with 2 second collection cycle creating total data ingestion load 2500 values/second. Data is stored in StreamHistory with default compression settings, and there is one aggregate (AVG) collected for each Variable. Additional data ingestion load is created by collecting 3 OPC events/s with standard attributes.

800

Small system reference configuration.

Small reference system
CPU4 Core (Broadcom BCM2837B0 quad-core A54 (ARMv8 running in ARMv7 32-bit compatibility mode), 1.4 GHz
RAM4 GB
DISKSSD 500GB (Samsung MZ-76E500BW)
OSLinux, Debian Buster

Resource consumptions are measured for the reference configuration and load, and presented in the table below separately for the key services as well as the total numbers.

ResourceSmall reference system
Disk space consumption4 GB + 125 MB/day
Total CPU consumption6.4 %
RAM consumption1.1 GB
Disk load1.6 %
(excluding backup)